firedoors 60

E-60-H Exterior 60 minute FRR hinged doorset, single

Designed for installations requiring a fire, smoke and acoustic door set, this versatile exterior fire door set has a 60 minute fire resistance rating (FRR). It is manufactured with a solid laminated veneer lumber (LVL) core and marine grade plywood facing (P-CORE). Unless you request a special finish, this door will be supplied sealer coated  on all six sides, ready for painting. This is a hung door, which means it is supplied as a complete fire door set - door leaf, door jamb, seals and appropriate hardware.

Data Sheet

E-60-H: Exterior 60 minute FRR hinged doorset, single

Our most popular 60 minute FRR hinged exterior fire, smoke and acoustic door set, the E-60-H is available in singles. The door leaf is a solid laminated veneer lumber (LVL) core faced with marine grade plywood (P-CORE). The standard door set is supplied sealer coated on all six sides ready for priming and painting. 

  • Leaf sizes up to Singles 2420 high x 916 or 2134 x 1052
  • Thickness 54 mm
  • Weight 24 kg /m2
  • Acoustic singles and doubles up to STC 34 

  • Paint quality factory sealed
  • 1 mm stainless steel kickplate to 1000 mm – inside only
  • 7 mm hardwood clashing to hinge edge 
  • 7 mm hardwood clashing to leading edge of (Flush pairs & Singles) 

32mm hardwood timber (types 1, 2 & 3), width 91 – 350 mm, planted stops (32 x 16), full width available at extra cost
 (steel jambs are temporarily unavailable) or 1.6 mm galv steel (types 5, 6 & 7 & Korok), paint quality or powdercoat options available

  • T1 – Timber

    T1 Timber Flat Jamb

    Timber flat for architrave

  • T2 – Timber

    fire door jamb

    Grooved for wall lining to suit (12 mm reveals)

  • T3 – Timber

    timber rebated fire door jamb

    Rebated for wall lining to suit (non-standard surcharge may apply)

  • Timber - Full width planted stop

    fire door jambs diagram

    PDF

    Available for all timber profiles (non-standard surcharge applies)

Not available for exterior door sets.

The minimum requirement is for a fire door to be self-closing and self-latching. Hardware must be selected from NZ Fire Doors’ Approved Hardware list from the column ‘60 min’. Fitting any hardware that inhibits self-closing or self-latching is not approved by NZS 4520

IMPORTANT: Fitting untested or inappropriate hardware may affect the performance of the door and will therefore void the warranty.

Download the Technical Compliance Statement